Lighting Equipment.
![]() |
![]() |
||||
![]() |
|||||
|
Geometric
Range
|
Standard
Recessed Luminaire
|
Surface
Mounted Luminaire
|
|||
![]() |
![]() |
![]() |
|||
|
Lunar
Downlighter
|
Universal
Luminaire
|
||||
|
Louvres,
Prismatics and Accessories
|
|||||
![]() |
![]() High Frequency & Emergency Fitting |
||||
|
T5
Recessed Luminaire
|
Louvres
& Diffusers
~ All standard EuroLite louvres are designed for lift and tilt
retention into modular tee grid systems. Manufactured
from high grade aluminium they are
designed
to meet particular lighting requirements.
There is a large choice of low brightness and category rated louvres to be used
in
conjunction with the luminaires.
The Cat 2A louvre
has been specially designed to be used with Alugrid15/08
and 15/16, as the longer flange allows it to sit flush with the grid.
The Low Brightness
louvre is low cost and aluminium bladed for general use
where no specific category rating is required.
The Square Specular
louvre is a lighting controller for use primarily in areas where
VDUs are used.
Circular Specular
louvres should be used in areas where decorative effect and lighting
appeal is important. The louvres are precision moulded in styrene, acrylic or
fire
retardant styrene. The surface is coated with an acrylic base prior to vacuum
metalising
to provide the specular mirror finish.
All louvres are
manufactured from high grade aluminium, featuring wedge shaped crossblades
that have been tested to LG3 and comply with the requirements of Category 2
(65º cut off)
and Category 3 (75º cut off).
Firefly Canopies
~ The Firefly Canopy offers a 1 hour fire performance,
complies with BS476, and has been tested in conjunction with the EuroLite.
It is supplied with fixings and is quick and easy to install.
The canopy is manufactured from a high performance material and is non-respirable
with virtually no fibre migration.
Firefly Downlighter Canopies are specifically designed for use with downlighters,
to contain the spread of fire and fulfills the requirements of building regulations.
Fire-Resistant
Light Box for exposed grid system.
Eurolite ES Module
A standard luminaire in a wide range of sizes to suit most ceiling layouts
~ for use with 15mm and 24 mm exposed grid systems only, and can be used with
a wide
range of louvres and diffusers ~ Louvres and diffusers are easily changed to
meet new performance
Eurolite Universal
Module Available in 600 x600mm size only ~ for use with
15mm and 24 mm exposed grid systems only, as well as Alugrid, Omega bar and
spring tee systems
~ Supplied with easily removable gear tray cover
~ No brackets required, rests directly on tee section with locking table
~ Lightweight fitting designed so that no additional supports are required for
the grid
Lighting
Calculation Charts.
Low Brightness Louvre
|
600
x 600mm ~ 500 Lux - LD. Lumens/lamp ~ 1100
|
600
x 1200mm ~ 500 Lux - LD. Lumens /lamp ~ 2800
|
|
Room
Length & Width (metres)
|
||||||||
|
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
|
3
|
3
|
4
|
5
|
6
|
6
|
7
|
8
|
9
|
|
4
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
11
|
|
5
|
5
|
6
|
7
|
8
|
10
|
11
|
12
|
13
|
|
6
|
6
|
7
|
8
|
10
|
11
|
12
|
14
|
15
|
|
7
|
6
|
8
|
10
|
11
|
12
|
14
|
16
|
18
|
|
8
|
7
|
9
|
11
|
12
|
14
|
16
|
17
|
19
|
|
9
|
8
|
10
|
12
|
14
|
16
|
17
|
19
|
21
|
|
10
|
9
|
11
|
13
|
15
|
18
|
19
|
21
|
24
|
|
Room
Length & Width (metres)
|
||||||||
|
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
|
3
|
1
|
1
|
2
|
2
|
2
|
3
|
3
|
3
|
|
4
|
1
|
2
|
2
|
3
|
3
|
3
|
4
|
4
|
|
5
|
2
|
2
|
3
|
3
|
4
|
4
|
5
|
5
|
|
6
|
2
|
3
|
3
|
4
|
4
|
5
|
5
|
6
|
|
7
|
2
|
3
|
4
|
4
|
5
|
5
|
6
|
7
|
|
8
|
3
|
3
|
4
|
5
|
5
|
6
|
7
|
7
|
|
9
|
3
|
4
|
5
|
5
|
6
|
7
|
7
|
8
|
|
10
|
3
|
4
|
5
|
6
|
7
|
7
|
8
|
9
|
Category 2. Wedge Louvre.
| 600 x 600mm ~ 500 Lux - LD. Lumens/lamp ~ 1100 |
600
x 1200mm ~ 500 Lux - LD. Lumens /lamp ~ 2800
|
|
Room
Length & Width (metres)
|
||||||||
|
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
|
3
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
|
4
|
4
|
5
|
6
|
8
|
9
|
10
|
11
|
12
|
|
5
|
5
|
6
|
8
|
9
|
10
|
12
|
14
|
14
|
|
6
|
6
|
8
|
9
|
11
|
13
|
14
|
15
|
17
|
|
7
|
7
|
9
|
11
|
13
|
14
|
16
|
18
|
20
|
|
8
|
8
|
10
|
12
|
14
|
16
|
18
|
20
|
22
|
|
9
|
9
|
11
|
14
|
15
|
18
|
20
|
22
|
25
|
|
10
|
10
|
12
|
14
|
17
|
20
|
22
|
25
|
27
|
|
Room
Length & Width (metres)
|
||||||||
|
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
|
3
|
1
|
1
|
2
|
2
|
2
|
3
|
3
|
3
|
|
4
|
1
|
2
|
2
|
3
|
3
|
3
|
4
|
4
|
|
5
|
2
|
2
|
3
|
3
|
4
|
4
|
5
|
5
|
|
6
|
2
|
3
|
3
|
4
|
4
|
5
|
5
|
6
|
|
7
|
2
|
3
|
4
|
4
|
5
|
5
|
6
|
7
|
|
8
|
3
|
3
|
4
|
5
|
5
|
6
|
7
|
7
|
|
9
|
3
|
4
|
5
|
5
|
6
|
7
|
7
|
8
|
|
10
|
3
|
4
|
5
|
6
|
7
|
7
|
8
|
9
|