PPL can supply
& install all your drywall, structural fire protection and firestopping
product requirements for all types of constructions. Access to all the major UK and European manufacturers, including British Gypsum, Lafarge, Knauf, Cape Calsil, Promat, Rockwool and many others ensure customers can be provided with whatever systems they require. We stock a vast array of metal systems, fixings, coatings and complementary accessories ensuring you get all your requirements on one delivery. We also provide independent guidance on product selection, technical advice and back it all up with a comprehensive installation service. |
![]() |
||||||||||||||||||||||||||||||||
| Single Membrane Integrity Only Fire Barrier | |||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||
| |
Lightweight | ||||||||||||||||||||||||||||||||
| Versatile | |||||||||||||||||||||||||||||||||
| Easily Modified | |||||||||||||||||||||||||||||||||
| Waterproof | |||||||||||||||||||||||||||||||||
| Tested to BS476 Parts 20/22 | |||||||||||||||||||||||||||||||||
| Easy to handle | |||||||||||||||||||||||||||||||||
| Simple to fix | |||||||||||||||||||||||||||||||||
|
Cost effective, lightweight fire barrier for up to 1 hour compartmentation of voids and above fire rated walls where integrity only is required. (For insulated requirements use Lancaster Fireshield Total Comfort Fire Barrier). |
|||||||||||||||||||||||||||||||||
|
Fireshield Total Comfort |
|||||||||||||||||||||||||||||||||
|
Tested
for top performance |
|||||||||||||||||||||||||||||||||
| Fireshield Total Comfort can be used as a half hour fire and cavity barrier in a single 50mm blanket or up to one and a half hours when two 50mm blankets are used together. | |||||||||||||||||||||||||||||||||
| Fireshield Total Comfort has been tested or conforms to the following standards: | |||||||||||||||||||||||||||||||||
| BS
476: Part 4, BS 476: Part 6, BS 476: Part 7, BS 476: Part 22, |
1970
Non Combustibility of Building Materials. 1989 Fire Propagation of Building Materials. 1987 Surface Spread of Flame. 1987 Fire Test for Building Materials in Non Loadbearing Elements of Construction |
||||||||||||||||||||||||||||||||
| The half-hour cavity barrier performance was tested to BS476: Part 22 at Warrington Fire Research Centre in 1987 (Report No. WARRES 41584). The test showed 62 minutes stability and integrity before being discontinued and 20 minutes insulation. | ![]() |
The one-hour barrier was tested to BS476: Part 22 at Warrington Fire Research Centre in 1989 (Report No. WARRES 46351). This test showed 105 minutes stability and integrity before being discontinued, and 89 minutes insulation. | ![]() |
||||||||||||||||||||||||||||||
| Knauf | |||||||||||||||||||||||||||||||||
|
Framed
Steelwork Encasement |
|||||||||||||||||||||||||||||||||
| Fire Resistant Light Box. | |||||||||||||||||||||||||||||||||
| For use on an exposed grid system
(AMF System C) as a fire-resistant light-box. 60 minutes fire resistance using 19mm thick material (600 x 600mm): Tested to BS476:Part 21: 1987, report no WARRES 102642. |
|||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||
|
Side panels
interlock together and with the exposed tee grid system. |
|||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||
| The
Firefly Canopy offers a 1 hour fire performance, complies with BS476, and
has been tested in conjunction with the EuroLite. It is supplied with fixings and is quick and easy to install. The canopy is manufactured from a high performance material and is non-respirable with virtually no fibre migration. Firefly Downlighter Canopies are specifically designed for use with downlighters, to contain the spread of fire and fulfills the requirements of building regulations. |
|||||||||||||||||||||||||||||||||